The effects of normal human variability and hand activity on sensory testing with the full Semmes-Weinstein monofilaments kit
- PMID: 11866352
- DOI: 10.1053/hanthe.2002.v15.01548
The effects of normal human variability and hand activity on sensory testing with the full Semmes-Weinstein monofilaments kit
Abstract
The first part of this study aimed to determine the effect of human variability on assessment using Semmes-Weinstein monofilaments. Fifteen healthy subjects were tested using a full monofilament kit of known calibration. When the subjects were retested, they responded to a different filament 48% of the time. The second part of the study aimed to determine the effects of vigorous hand activity on sensation, as measured with Semmes-Weinstein monofilaments. Forty randomly selected healthy subjects were assessed before and after they performed a brief, standardized gripping activity. After hand activity, the subjects responded to a different filament 53% of the time. In both parts of this study, the changes in monofilament results were random in direction and magnitude. The number of changes did vary between test sites, the radial nerve sites being most variable and the ulnar nerve sites least variable. It is concluded that the results of testing with the five smallest monofilaments in the full Semmes-Weinstein kit were not reliable in normal subjects and that they did not detect change in sensory function in normal subjects.
Similar articles
-
Fifty years of somatosensory research: from the Semmes-Weinstein monofilaments to the Weinstein Enhanced Sensory Test.J Hand Ther. 1993 Jan-Mar;6(1):11-22; discussion 50. J Hand Ther. 1993. PMID: 8343870
-
A Comparison of the Sensitivity of Brush Allodynia and Semmes-Weinstein Monofilament Testing in the Detection of Allodynia Within Regions of Secondary Hyperalgesia in Humans.Pain Pract. 2017 Jan;17(1):16-24. doi: 10.1111/papr.12418. Epub 2016 Mar 3. Pain Pract. 2017. PMID: 26936430 Clinical Trial.
-
Normal values for sensory thresholds in the cervical dermatomes: a critical note on the use of Semmes-Weinstein monofilaments.Am J Phys Med Rehabil. 1999 Jan-Feb;78(1):24-9. doi: 10.1097/00002060-199901000-00007. Am J Phys Med Rehabil. 1999. PMID: 9923425
-
Sensory thresholds of normal human feet.Foot Ankle Int. 2000 Jun;21(6):501-4. doi: 10.1177/107110070002100609. Foot Ankle Int. 2000. PMID: 10884110
-
Identifying patients with diabetes mellitus who are at risk for lower-extremity complications: use of Semmes-Weinstein monofilaments.Phys Ther. 1996 Jan;76(1):68-71. doi: 10.1093/ptj/76.1.68. Phys Ther. 1996. PMID: 8545495 Review.
Cited by
-
Buckling Force Variability of Semmes⁻Weinstein Monofilaments in Successive Use Determined by Manual and Automated Operation.Sensors (Basel). 2019 Feb 16;19(4):803. doi: 10.3390/s19040803. Sensors (Basel). 2019. PMID: 30781464 Free PMC article.
-
Long Term Cosmetic Application Improves Tactile Discrimination in the Elderly; a New Psychophysical Approach.Front Aging Neurosci. 2019 Jun 28;11:164. doi: 10.3389/fnagi.2019.00164. eCollection 2019. Front Aging Neurosci. 2019. PMID: 31316373 Free PMC article.
-
Hand assessment in older adults with musculoskeletal hand problems: a reliability study.BMC Musculoskelet Disord. 2011 Jan 7;12:3. doi: 10.1186/1471-2474-12-3. BMC Musculoskelet Disord. 2011. PMID: 21214921 Free PMC article.
-
Contribution of Loss of Large Fiber Function to Pain in 2 Samples of Oncology Patients.Clin J Pain. 2019 Jan;35(1):37-42. doi: 10.1097/AJP.0000000000000649. Clin J Pain. 2019. PMID: 30247200 Free PMC article.
-
Tamai zone -I and -II replantation versus reconstruction with local flaps: retrospective analysis for functional and cosmetic results.Case Reports Plast Surg Hand Surg. 2024 Feb 26;11(1):2320882. doi: 10.1080/23320885.2024.2320882. eCollection 2024. Case Reports Plast Surg Hand Surg. 2024. PMID: 38415206 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources