AMTAS: automated method for testing auditory sensitivity: validation studies
- PMID: 20109081
- DOI: 10.3109/14992020903092608
AMTAS: automated method for testing auditory sensitivity: validation studies
Abstract
Three studies are reported assessing the validity of AMTAS, an automated method for obtaining an audiogram, including air- and bone-conduction thresholds (stimuli delivered by a forehead-placed transducer) with masking noise presented to the non-test ear. In Study 1, six subjects at each of three sites were tested using manual audiometry by two audiologists at each site. The mean differences between the audiograms for the paired audiologists provided a measure of the reliability of traditional audiometry. In Study 2, thirty subjects (5 normal hearing, 25 hearing impaired) were tested using AMTAS and manual audiometry. For air-conduction thresholds, AMTAS-manual differences were similar to inter-tester differences in Study 1, but for bone-conduction thresholds, the former were larger. Two possible sources of the greater differences were identified, (1) incorrect reference-equivalent threshold force levels for forehead bone conduction, and (2) a differential effect of middle-ear disease on forehead and mastoid bone-conduction thresholds. In Study 3, intersubject variability was studied for forehead and mastoid bone-conduction thresholds. The results indicate similar variability for the two placement sites.
Similar articles
-
Occlusion effect: bone conduction speech audiometry using forehead and mastoid placement.Audiology. 1977 Nov-Dec;16(6):522-9. doi: 10.3109/00206097709080023. Audiology. 1977. PMID: 921610
-
Clinical validation of the AMTAS automated audiometer.Int J Audiol. 2013 May;52(5):342-9. doi: 10.3109/14992027.2013.769065. Epub 2013 Apr 3. Int J Audiol. 2013. PMID: 23548148
-
AMTAS(®): automated method for testing auditory sensitivity: II. air conduction audiograms in children and adults.Int J Audiol. 2011 Jul;50(7):434-9. doi: 10.3109/14992027.2011.553206. Epub 2011 Mar 18. Int J Audiol. 2011. PMID: 21417674
-
Air conduction, bone conduction, and soft tissue conduction audiograms in normal hearing and simulated hearing losses.J Am Acad Audiol. 2015 Jan;26(1):101-8. doi: 10.3766/jaaa.26.1.11. J Am Acad Audiol. 2015. PMID: 25597465
-
Repeatability of high-frequency bone conduction thresholds.Ear Hear. 1987 Dec;8(6):343-6. doi: 10.1097/00003446-198712000-00010. Ear Hear. 1987. PMID: 3322900 Review.
Cited by
-
Does Exposure to Noise During Military Service Affect the Progression of Hearing Loss with Increasing Age?Trends Hear. 2022 Jan-Dec;26:23312165221076940. doi: 10.1177/23312165221076940. Trends Hear. 2022. PMID: 35128984 Free PMC article.
-
Development of Improved Software Intelligent System for Audiological Solutions.J Med Syst. 2018 Jun 2;42(7):127. doi: 10.1007/s10916-018-0978-6. J Med Syst. 2018. PMID: 29860544
-
Performance and Reliability Evaluation of an Automated Bone-Conduction Audiometry Using Machine Learning.Trends Hear. 2024 Jan-Dec;28:23312165241286456. doi: 10.1177/23312165241286456. Trends Hear. 2024. PMID: 39489159 Free PMC article.
-
Hearing Health Care Utilization Following Automated Hearing Screening.J Am Acad Audiol. 2021 Apr;32(4):235-245. doi: 10.1055/s-0041-1723041. Epub 2021 Jun 1. J Am Acad Audiol. 2021. PMID: 34062603 Free PMC article. Clinical Trial.
-
Automated Audiometry: A Review of the Implementation and Evaluation Methods.Healthc Inform Res. 2018 Oct;24(4):263-275. doi: 10.4258/hir.2018.24.4.263. Epub 2018 Oct 31. Healthc Inform Res. 2018. PMID: 30443414 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources