Measurement of tear film thickness using ultrahigh-resolution optical coherence tomography
- PMID: 23847319
- DOI: 10.1167/iovs.13-11920
Measurement of tear film thickness using ultrahigh-resolution optical coherence tomography
Abstract
Purpose: To visualize the precorneal tear film with ultrahigh-resolution spectral domain optical coherence tomography, enabling quantification of tear film thickness in healthy subjects.
Methods: A custom-built spectral domain optical coherence tomography system comprising a broadband titanium:sapphire laser operating at 800 nm and a high-speed charge coupled device (CCD) camera with a read-out rate of 47 kHz was used for measurement of precorneal tear film thickness. The system provides a theoretical axial resolution of 1.2 μm in tissue. The signal-to-noise ratio close to the zero delay was measured with 94 dB. A total of 26 healthy subjects were included in this study. Measurement was started immediately after blinking and averaged over a period of 1 second. In a subset of eight healthy subjects, the reproducibility of the approach was studied by measuring the tear film thickness every 10 minutes over 1 hour.
Results: The average central tear film thickness of the measured population was 4.79 ± 0.88 μm. Reproducibility was very high, with an intraclass correlation coefficient of 0.97. A breakup of the tear film was observed in one subject after 14 seconds.
Conclusions: Our data indicate that the human precorneal tear film can be measured with excellent reproducibility using ultrahigh-resolution optical coherence tomography. This technique may be a valuable tool in the management of dry eye syndrome.
Trial registration: ClinicalTrials.gov NCT01746602.
Keywords: dry eyes; optical coherence tomography; tear film thickness.
Similar articles
-
Precise thickness measurements of Bowman's layer, epithelium, and tear film.Optom Vis Sci. 2012 May;89(5):E795-802. doi: 10.1097/OPX.0b013e3182504346. Optom Vis Sci. 2012. PMID: 22488267
-
Visualization of the precorneal tear film using ultrahigh resolution optical coherence tomography in dry eye.Eye Contact Lens. 2012 Jul;38(4):240-4. doi: 10.1097/ICL.0b013e318257a108. Eye Contact Lens. 2012. PMID: 22735625 Free PMC article.
-
Comparison of two artificial tear formulations for dry eye through high-resolution optical coherence tomography.Clin Exp Optom. 2011 Nov;94(6):549-56. doi: 10.1111/j.1444-0938.2011.00632.x. Epub 2011 Sep 19. Clin Exp Optom. 2011. PMID: 21929716 Clinical Trial.
-
Future directions in non-invasive measurements of tear film surface kinetics.Optom Vis Sci. 2012 May;89(5):749-59. doi: 10.1097/OPX.0b013e318250192d. Optom Vis Sci. 2012. PMID: 22466103 Review.
-
Role of the tear film in the optical quality of the human eye.J Cataract Refract Surg. 2007 Sep;33(9):1631-5. doi: 10.1016/j.jcrs.2007.06.019. J Cataract Refract Surg. 2007. PMID: 17720082 Review.
Cited by
-
Human meibum and tear film derived (O-acyl)-omega-hydroxy fatty acids in meibomian gland dysfunction.Ocul Surf. 2021 Jul;21:118-128. doi: 10.1016/j.jtos.2021.05.009. Epub 2021 May 28. Ocul Surf. 2021. PMID: 34052415 Free PMC article.
-
The Development and Clinical Application of Innovative Optical Ophthalmic Imaging Techniques.Front Med (Lausanne). 2022 Jun 30;9:891369. doi: 10.3389/fmed.2022.891369. eCollection 2022. Front Med (Lausanne). 2022. PMID: 35847772 Free PMC article. Review.
-
THz imaging system for in vivo human cornea.IEEE Trans Terahertz Sci Technol. 2018 Jan;8(1):27-37. doi: 10.1109/TTHZ.2017.2775445. Epub 2017 Dec 7. IEEE Trans Terahertz Sci Technol. 2018. PMID: 29430335 Free PMC article.
-
Measurement of a multi-layered tear film phantom using optical coherence tomography and statistical decision theory.Biomed Opt Express. 2014 Nov 24;5(12):4374-86. doi: 10.1364/BOE.5.004374. eCollection 2014 Dec 1. Biomed Opt Express. 2014. PMID: 25574445 Free PMC article.
-
Fourier-Domain OCT Imaging of the Ocular Surface and Tear Film Dynamics: A Review of the State of the Art and an Integrative Model of the Tear Behavior During the Inter-Blink Period and Visual Fixation.J Clin Med. 2020 Mar 2;9(3):668. doi: 10.3390/jcm9030668. J Clin Med. 2020. PMID: 32131486 Free PMC article. Review.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous