Comparison of two fat-suppressed magnetic resonance imaging pulse sequences to standard t2-weighted images for brain parenchymal contrast and lesion detection in dogs with inflammatory intracranial disease
- PMID: 25395066
- DOI: 10.1111/vru.12220
Comparison of two fat-suppressed magnetic resonance imaging pulse sequences to standard t2-weighted images for brain parenchymal contrast and lesion detection in dogs with inflammatory intracranial disease
Abstract
T2-weighted (T2w) sequences are commonly relied upon in magnetic resonance imaging protocols for the detection of brain lesions in dogs. Previously, the effect of fluid suppression via fluid-attenuated inversion recovery (FLAIR) has been compared to T2-weighting with mixed results. Short tau inversion recovery (STIR) has been reported to increase the detection of some CNS lesions in people. The purpose of the current study was to evaluate the effect of fat suppression on brain parenchymal contrast resolution and lesion detection in dogs. We compared three sequences: T2w images, STIR, and T2w FLAIR with chemical fat suppression (T2-FLAIR-FS) in dogs with meningoencephalitis. Dogs with meningoencephalitis and dogs with idiopathic epilepsy were retrospectively identified and anonymized. Evaluators recorded the presence or absence of lesions within 12 predetermined brain regions on randomized sequences, viewing and scoring each sequence individually. Additionally, signal-to-noise ratios, contrast-to-noise ratios, and relative contrast (RC) were measured in a reference population. Short tau inversion recovery sequences had the highest RC between gray and white matter. While descriptively more lesions were identified by evaluators on T2-FLAIR-FS images, there was no statistical difference in the relative sensitivity of lesion detection between the sequences. Nor was there a statistical difference in false lesion detection within our reference population. Short tau inversion recovery may be favored for enhanced anatomic contrast depiction in brain imaging. No benefit of the inclusion of a fat-suppressed T2-FLAIR sequence was found.
Keywords: MRI; brain; dog; fat suppression; imaging.
© 2014 American College of Veterinary Radiology.
Similar articles
-
Comparing lesion detection of infratentorial multiple sclerosis lesions between T2-weighted spin-echo, 2D-FLAIR, and 3D-FLAIR sequences.Clin Imaging. 2018 Sep-Oct;51:229-234. doi: 10.1016/j.clinimag.2018.05.017. Epub 2018 May 29. Clin Imaging. 2018. PMID: 29879598
-
Comparison of magnetic resonance imaging sequences in dogs with multi-focal intracranial disease.J Small Anim Pract. 2008 Dec;49(12):634-40. doi: 10.1111/j.1748-5827.2008.00628.x. Epub 2008 Aug 5. J Small Anim Pract. 2008. PMID: 18684139
-
Unique topographic distribution of greyhound nonsuppurative meningoencephalitis.Vet Radiol Ultrasound. 2012 Nov-Dec;53(6):636-42. doi: 10.1111/j.1740-8261.2012.01963.x. Epub 2012 Jun 29. Vet Radiol Ultrasound. 2012. PMID: 22742427
-
Most commonly used sequences and clinical protocols for brain and spine magnetic resonance imaging allowing better identification of pathological changes in dogs.Pol J Vet Sci. 2013;16(1):157-63. doi: 10.2478/pjvs-2013-0024. Pol J Vet Sci. 2013. PMID: 23691592 Review.
-
Targeted magnetic resonance imaging (tMRI) of small changes in the T1 and spatial properties of normal or near normal appearing white and gray matter in disease of the brain using divided subtracted inversion recovery (dSIR) and divided reverse subtracted inversion recovery (drSIR) sequences.Quant Imaging Med Surg. 2023 Oct 1;13(10):7304-7337. doi: 10.21037/qims-23-232. Epub 2023 Aug 15. Quant Imaging Med Surg. 2023. PMID: 37869282 Free PMC article. Review.
Cited by
-
Hyperintensity of Cerebrospinal Fluid on T2-Weighted Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Caused by High Inspired Oxygen Fraction.Front Vet Sci. 2017 Dec 18;4:219. doi: 10.3389/fvets.2017.00219. eCollection 2017. Front Vet Sci. 2017. PMID: 29326953 Free PMC article.
-
Consensus recommendations on standardized magnetic resonance imaging protocols for multicenter canine brain tumor clinical trials.Vet Radiol Ultrasound. 2018 May;59(3):261-271. doi: 10.1111/vru.12608. Epub 2018 Mar 9. Vet Radiol Ultrasound. 2018. PMID: 29522650 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical